Longview Power
THERMOPHASE treatment of an operating power-plant condenser at Longview Power, with support from the DOE National Energy Technology Laboratory.
← All power demonstrationsHow THERMOPHASE is used in power generation →

Completed field demonstration
Demonstration summary
- Customer
- Longview Power, under the DOE Office of Fossil Energy Crosscutting Research Program, managed by the National Energy Technology Laboratory (NETL)
- Application
- Main condenser of an operating power plant
- Dates
- Program 2018–2021; final technical report published August 2023
- Status
- Completed
Result
Plant performance was monitored for two years after application; over that period, condenser back pressure was 0.26 ± 0.13 inHg lower
Economic significance
Over the two years following application: an estimated $3.35M in fuel savings, 136 million lbs less CO₂ emitted and 1.287 billion gallons less water withdrawn, as reported in the DOE final technical report
The problem
Condenser fouling and heat-transfer loss raise condenser back pressure, increasing fuel use, CO₂ emissions and water withdrawal
What was done
THERMOPHASE was evaluated in controlled environments, where improved heat transfer and reduced fouling were observed, then applied to the plant’s main condenser during operation. Plant performance was monitored afterward.
Limitations Results reflect one plant’s operating conditions. The back-pressure reduction carries an uncertainty of ±0.13 inHg, and the fuel, CO₂ and water figures are estimates derived from it.