THERMOPHASE APPLICATIONS

Find where THERMOPHASE fits

Different facilities face different cooling problems. Choose your market to see the problem THERMOPHASE addresses, the equipment it treats and how it is applied. Measured results are on Evidence and case studies.

CONDENSERS

Power generation

Operational challenge Condenser fouling and degraded heat transfer raise heat rate, reduce output margin and drive tube cleanings that are often tied to outage schedules.

Potential benefit Improved condenser heat transfer, slower refouling and longer intervals between cleanings, supporting plant economics and reliability.

How it applies Circulated through the condenser cooling-water system to treat tube surfaces.

Where it is used Power-plant condensers at coal-fired, combined-cycle (CCGT) and nuclear plants.

Proof point

Completed field demonstration THERMOPHASE treated an operating power-plant condenser at Longview Power, with DOE/NETL support.

Plant results depend on cooling-water source, fouling regime and operating profile.

CHILLERS AND INDUSTRIAL COOLING

Commercial and industrial cooling

Industrial cooling covers

  • Building chillers
  • District energy plants
  • Chiller and heat-exchanger systems
  • Data-center cooling

Operational challenge Fouled condensers raise chiller energy use and maintenance across campuses, hospitals and federal facilities.

Potential benefit Better performance from existing chillers, lower energy cost and longer intervals between tube cleanings, with a projected payback measured in months.

How it applies Treatment of chiller condenser water loops, with performance tracked against a baseline.

Where it is used Heat-transfer surfaces such as chiller condensers and evaporators and plate heat exchangers, in stainless steel, copper, copper-nickel, aluminum and titanium.

Proof point

Field demonstration · reporting in progress DoD ESTCP demonstration on 850-ton chillers at a Navy hospital.

Economics differ by site, load and energy price.

DATA-CENTER COOLING

Data centers

Operational challenge Chiller performance sets how much heat a facility can reject. Fouling erodes cooling headroom on the hottest, highest-load days and adds to energy cost.

Potential benefit Protected condenser performance and cooling headroom, with results verified against a measured baseline.

How it applies Asset-level treatment of the chillers you select: each is isolated, THERMOPHASE circulates for about one hour, and the chiller returns to service with no operational changes. Compatible with existing water-treatment programs.

Proof point

No data-center results have been reported yet. Chiller results from other sites indicate potential, not data-center performance.

MARINE

Marine and seawater systems

Operational challenge Seawater systems foul quickly, adding maintenance and reducing heat-exchanger and engine-cooling performance.

Potential benefit Fouling resistance and preserved thermal performance in demanding seawater service.

How it applies Circulation through seawater piping, heat exchangers, aftercoolers and shipboard chillers.

Proof point

Completed program THERMOPHASE began in a U.S. Navy SBIR program for submarine seawater systems.

Marine is where THERMOPHASE began; current commercial availability is being defined.